Бренд |
CJ |
Место происхождения |
Zhejiang China (Mainland) |
Номер Модели |
XMT*808 |
Использование |
Промышленность |
Принцип |
Терморегулятор |
XMT*808 seriesdigital PIDtemperature controller uses nowadays the most advanced monolithic microcomputer as mainframe,reduce peripheral assembly,and improve the reliabilityIt adopts the control method of vague theory combined with traditional PID control, and make the control process with the advantage of rapid responsesmall overshoothigh steady state precision. It is intelligence temperature controller with the function of high performancehigh reliabilitycomplete input,its function is suitable to all the occasion needed temperature measurement and control,also be compatible with other industrial parameter measurement and control. It adopts modular structure,further improve overall performanceThe meter is operated with 4-keys,dual row 4-LED display for displaying the measurement value and set value or measurement value and output value, with manual /automatic switch and setting itself functionwith characteristic of small volumelow power consumptionconvenient operationsteady and reliable of runningThey are now widely used for the automatic control system over the area of machinery, chemical, ceramics, light industry, metallurgy, petrifaction, heat treatment industry. Technical standard1. Input and rangeone meter can be compatible (1) Thermocouple: K (-50 1300oC), S (-50 +1700oC), T (-200 +350oC), E (0 800oC), J ( 0 1000oC), B (0 1800oC), N (0 1300oC), WRe (0 2300oC) (2) Thermal resistance: CU50 (-50 150oC) PT100 (-20 600oC) (3) Linearity voltage05V15V01V0100mV020mV (4) Linearity currentwith diffluent resistance010mA020mA420mA (5) Linearity input: -1999 +9999 (user freely setting) 2. Precision (1) Input by thermal resistance , linearity voltage and linearity current 0.5F.S±1 (2) Thermocouple input adopt copper resistance or freezing compensate cold end 0.5 F.S±1 (3) Although the meter can measure B, S, WRE during the temperature 0 600oC,its measurement could not reach 0.5 class (4) differentiate rate1, 0.1 3. Response time: ≤0.5s (filter parameter sets 0) 4. Adjusting mode (1) ON/OFF control methodReturn difference can be adjusted (2) Common PID controlwith the parameter of self-setting function (3) Intelligence adjustment(including vague PID adjustment and advanced control algorithm with the parameter of self-setting function) 5. Output specificationit make out directly output parameter modularity or without modularity (1) The switch of relay contact point outputopen+ closed250VAC/7A or 30VDC/10A (2) SSR voltage:12VDC/30mA(apply for driving SSR relay) (3) Contact point output with controllable silicon: can contact 5 500A two directions controllable silicon;2 separate directions controllable silicon opposite direction parallel. (4) Liner electric current output initial current and terminal current value can be defined when the output is 0 24mAvoltage range 11 23VDC 6. Communication Support RS485communication mode,adopt AIBUS communication agreement,and baud rate support the below selection 1200bps4800bps7200bps9600bps 7. Alarm: Support two passive contact output,relay contact 250VAC/7AIt has four methods including upper limit, lower limit, positive deviation ,negative deviation .It can output 2 ways at most 8. Tolerance for pressure when it is segregatedBetween electric power ,relays contact and signals end ,do 2000V pressure tolerance test 1s,there is no abnormal phenomenon; 9. Movement with hand: Automatic /Manual 10.Power supply: (1) 85V-242VAC,50-60HZpower consumption ≤4W (2) 24VDC/AC power consumption≤4W (3) 220VAC±10% 50HZpower consumption≤4W 11. working circumstance Environment temperature:0 50,humidity ≤85,no corrode and strong electromagnetism disturb 12. Product authentication XMT*-808 series temperature meter acquire CE authentication and ROHS Environmental Protection authentication. Product code XMT ___ 8 ___ 8 ____ (1) (2) (3) (4) (5) 1. The surface dimensionBlank: 160×80×120 Installation hole 152×76 A: 96×96×110 Installation hole 92×92 D:72×72×110 Installation hole 68×68 E: 48×96×110 Installation hole 44×92 F:96×48×110 Installation hole 92×44 S:80×160×120 Installation hole 76×156G:48×48×110 Installation hole 44×442. Control Mode: '8' four key set, two row LED display,,fuzzy control.3. Additional alarm: '0' no alarm ; '1' one group alarm ; '3' two group alarms; '5' voice alarm4. Signal input type '8' freely exchange signal5. Suffix Main control output method 'Blank' : relays open and closed contact output 'A' : Single-phase over-zero spark pulse 'A3' :Three-phase over-zero spark pulse; BSingle-phase shift-phase spark pulse'B3' : Three-phase shift-phase spark pulse'C' : 010mA or 420mA constant electric current output 'E' : Linearity voltage output 'G' : ON/OFF solid state relaySSRadjustment outputAuxiliary ways 'K' : with RS485 or RS232 communication module interface 'Wt': with micro-printer output signal'V' : DC24VDC12VDC5V output 'P' : 30 segment program