Место происхождения |
Guangdong China (Mainland) |
Бренд |
Prostar |
Номер Модели |
HM40K |
Масса |
310Kg |
Выходное напряжение |
220V ±1% |
Neptune SeriesLow FrequencyOnlineUPS→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→ Applied Scope: Data Center Medical And Health Industrial Equipment Energy And Electricity Financial And Securities Large Internet Computer Room Postal And Telecommunications Industrial And Commercial tax affair Main Characteristics:Durable and reliable design of industrial-type modular structure, combined with full digital DSP control technology core system, make this product not only can be used for N+1/N+X redundancy and the ability of enlarge the capacity, but also permit different power and different times of the UPS could be in parallel. It greatly reduced the user's pre-and post-purchasing costs, and increased capacity costs, but also expanded upper spaces of increasing capacity.Technical Specification:ModeHM40KCapacity(VA/W)40K/32KBattery Voltage384V UPS Efficiency≥95% Noise53 62dB (Distance 1m) Size(W×D×H mm)550×720×1200 Weight(Kg)(Excluding battery)310InputVoltage3 phases 4 wires and ground, 380V ± 20% Frequency50Hz/60Hz ± 5% (Automatically) Power Factor≥0.95 Inverter outputVoltage220V ±1% Frequency50Hz/60Hz±0.05%(By battery) Harmonic distortionLinear load< 3%, Non-linear load < 5% Imbalance VoltageBalance load ≤ 1%, Imbalance load ≤3% Phase shift angleBalance load≤±1°, Imbalance load≤±2° Transient responseOutput at 0 50% 100% ≤5%, response≤10ms Overload Capacitance110%≥300 Min, 125%≥10 Min, 150%≥ 1 Min Crest Factor3:1 Wave FormPure Sine Wave Transfer time0 ms BatteryMax.charging current0.2A x C10 Charging Time(Standard)12 hours SystemProtective functionInput Over-voltage, under-voltage; Output overload, short-circuit;Inverter over-temperature; Battery under-voltage, over-voltage Running temperature& Humidity0°C-40°C degree Celsius,less than 95%(without condensing) Altitude<1000m(with increase of 100m, it will reduce output of 1% )max 4000m Communication interfaceRS232 Remote signalDry contact ( battery low, battery discharging, bypass/fault); EPO Remote controlEPO and Bypass Degree of ProtectionIP20 (front door opened) Parallel modeN+1,N+X can be in parallel with different power capacity SoftwareInterface Windows9X,2000,NT,Me,XP,Linux,Novell,Macosx,NT4.0 Mean time between failures 300,000 Hours otherDustproof and damp-proof, isolating inverter transformer, Lightning Surge absorption, static switches and manual maintenance switch Noted: Product specifications will be updated, if you would like to know more lastest information, please contact us.