Место происхождения |
Zhejiang China (Mainland) |
Бренд |
CSR |
Номер Модели |
NA100-P |
NA100-P current sensor Applications: For the electronic measurement of currents: AC, DC IMPL.,etc.,with galvanic isolation between the primary (high power) and the secondary (electronic) circuits. Main technical data: 1. Primary normal current IPN: 100A r.m.s 2. Primary current, measuring range IP: 0 +/-150A 3. Measuring resistance: RMmin RMmax with +/-12V @ +/-100A max: 0 ohm 42 ohm @ +/-120A max: 0 ohm 14 ohm with +/-15V @ +/-100A max: 20 ohm 100 ohm @ +/-150A max: 20 ohm 25 ohm 4. Secondary normal current: 50mA rms 5. Conversion ratio: 1:2000 6. Supply voltage(+/-5%): +/-12V +/-15V 7. Current consumption: 10mA+ Secondary output current 8. Isolation test: Between the primary circuit to the secondary circuit: 2.5kVrms/50Hz/1min Accuracy – Dynamic performance data: 1. Accuracy @ IPN, TA=+25 oC , @+/-12V +/-15V: +/-0.7% 2. Non-linearity: better than +/-0.2% 3. Offset current: not more than +/-0.1mA(@+25oC) 4. Residual current @ IP=0 after an overload of 3xIP: +/-0.3mA 5. Thermal drift: +/-0.25mA(-25 oC +85 oC) +/-0.50mA(-40 oC +25 oC) 6. Reaction time @10% of IP max : less than 500ns 7. Response time: not more than 1us 8. di/dt accurately followed: better than 100A/us 9. Frequency Bandwidth (0.5dB): DC 0 200kHz General data: 1. Operating temperature: -40ºC +85ºC 2. Storage temperature: -40 oC +90 oC 3. Secondary coil resistance: not more than 120 ohm 4. Weight: 25g 5. Standards: EN 50155 Features: 1. Hall effect measuring principle 2. Galvanic isolation between primary and secondary circuit 3. Insulated plastic case made of white PPO recognized according to UL 94-V0 4. The whole current transducer comply with RoHS Directive completely