Тип дисплея |
Только цифровой |
Количество фаз |
Три фазы |
Место происхождения |
Jiangsu China (Mainland) |
Бренд |
Microstar |
Номер Модели |
P2000-D |
Энергетический диапазон измерения |
58-240V |
Класс точности |
0.5 |
Рабочая температура |
23 |
MAIN FEATURES - Accuracy: Class 0.5S, Class 1, IEC62053-21 - 3P3W, 3P4W - Measurement & Registration of KWh, Kvarh & KVAh - Maximum Demand Registration - Load Profile recording - TOU Control with flexible programming of 4 tariffs - Internal real-time clock and calendar with battery backup - Data storage in non-volatile memory - Fully AMR (Automated Meter Reading) compatible - Easily readable indication on LCD display with OBIS code+ MEASUREMENT AND REGISTRATION - Energy: KWh, kVarh, KVAh (All bi-directional metering) - Maximum Demand with date and time stamps - Load profile recording+ TOU (TIME OF USE) CONTROL - Tariff switching Int clock or Ext signal - Tariffs Up to 4 tariffs - Seasons Up to 4 tariff seasons - Daily profiles Up to 10 day profiles - Maximum Demand Up to 4 tariffs+ DATA STORAGE Energy - Current [T1...T4, Tsum] - Last 16 months [T1...T4, Tsum] Max Demand - Current [T1...T4, Tsum] - Last 16 months [T1...T4] + LOAD PROFILE - Integration period: 1, 5, 30 or 60 min - 420 days with integration period 60 min - Data Retention: 25 Years+ EVENTS REGISTRATION - Power outages with date & time - Per-phase voltage-loss with time stamps - Voltage-under/over with time stamps - Per-phase current-loss with time stamps - Exploitation time for each tariff - Last meter programming date & time - Reverse current flow indication on LCD+ COMMUNICATIONS - Optical interface IEC 62056-21 optional - Infrared interface Optional - RS 232/485 Optional+ DISPLAY - Cyclic data indication automatically or by keys - Data indication on LCD during power outages - 8 digit LCD, with 7 digit OBIS Code+ SECURITY - Meter programming by sealed button and password+ RATINGS - System 3P 3W, 3P 4W - Accuracy class Class 0.5S, Class 1 - Standard IEC 61036 - Reference voltage Un 3x57.7/100; 3x63.5/110 3x220/380; 3x230/400 Custom - Reference current Direct Connected 5(60)A, 10(120) CT Operated 1.5(6)A, 5(40) - Start Current Direct Connected 0.2% Ib Class 0.5S 0.4% Ib Class 1 CT Operated 0.1% Ib Class 0.5S 0.2% Ib Class 1 - Reference Frequency 50/60 Hz - Power consumption: In voltage circuit < 1 W; < 1 VA In current circuit < 0, 05 VA - Temperature ranges: Meter operating -30 C to +70 C Meter storage -45 C to +85 C Humidity: <= 95%+ INTERNAL REALT-TIME CLOCK WITH BACKUP BATTERIES - Time-keeping accuracy < 0.5 Sec / 24Hours - Clock operating with battery > 15 years + Inputs and Outputs - Electric pulse output(SO) Test output - LED test output 400 - 8000 imp/kWh - Push-buttons Display browsing Programming Protection+ CASE AND DIMENSION SIZES - Case Materials Reinforced Polycarbonate - UV Stabilized Cover Reinforced Polycarbonate - Terminal Material Bakelite - Insulation Protective Class II - Dimensions (mm) 274 x 167 x 66 - Weight 1.8 Kg - Water-proof IP51, IEC 529+ ACCOMPANIED SOFTWARE Bluestar Metering Program will be provided on request or With meters purchasing. This Windows-based application Can be used to program meter's parameters, read meter's Data and load profile curves.