газ (LPG) детектор (Авто закрыть клапан)

газ (LPG) детектор (Авто закрыть клапан)

Нинбо, Китай
Компания
86-574-62839119
winky li
Контактное лицо

Основные данные

Место происхождения Zhejiang China (Mainland)
Бренд JST
Номер Модели JST-A(W)
The gas detector Technical parameters 1.Induced Gas Natural gas,LPG(liquid petroleum gas),Coal gas 2.Power DC12V/AC220V 50HZ 3.Operating Current 50mA-400mA10%LEL 4.Alarm Concentration 10%LEL 5.Buzzer Volume: ≥70db at 1m 6.Operating Condition -10°C +50°C Relative humidity: <90%RH 7.Stability: under long time working condition, the discrepancy ≤±5%LEL 8.Repeatability: repeating alarm tests, discrepancy ≤±5%LEL 9.Alarm Sensitivity , discrepancy: ≤±5%LEL 10.Alarming Pattern: Acousto-optic alarm, Start valve controller, input networking signal 11.Power Consumption: ≤5W Firstly, the necessary testing is to determine the gas is heavier than air or is lighter than air: heavier than air gases are liquefied petroleum gas, etc.; lighter than air gases are natural gas, carbon monoxide, artificial gas, and biogas; Install the alarm in the right place according to the weight of the gas. (Refer to picture 3 on the right). When the gas is heavier than air: The alarm must be mounted over the ground and the height must be more than 31cm, and be away from the gas source within 1.5 meters radius. When the gas is lighter than air: The alarm must be mounted under the ceiling and the height must be less than 31cm, and be away from the gas source within 1.5 meters radius. Fix the mounting plate on the chosen position and then probe the detector into it and to have a check whether it is fastened or not. (Refer to picture4 on the right) (1) More attention should be paid when install it in the household. (2) Close distance to gas stoves is not permitted, in case of the heat of the stove flames. The position with heavy smoke should be avoided too, to prevent the mistaken alarm or the bad ventilation which may affect the sensitivity of the alarm.. (3) The alarm should not be placed around the ventilating fan or the windows or the shower room where the vapor is heavy. The white plug wire is just the AC 220V power cord.(If you use the AC 220V, then you only need the Acousto-optic alarm, there won’t be any red, black, yellow, blue, green wires along with the alarm. And if you use the DC 12V, then there won’t be a AC 220V power cord along with the alarm.) Update Date:2010/11/09 1:44:16

Условия поставки и упаковка

Packaging Detail: 20 pcs in one carton or according to yourself Delivery Detail: within 30days after receipt of your order
Порт: Ningbo and Shanghai

Условия оплаты

Аккредитив

Электронный перевод

Фотографии

    Восстановление пароля
    Для восстановления пароля, введите пожалуйста ниже емаил, на который производилась регистрация:
    Код для сброса пароля был выслан на указанный Вами Email
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    Произошла ошибка. Пожалуйста, проверьте введенные Емаил и повторите попытку.
    Ваш новый пароль:

    Имя не заполнено


    Выберите страну доставки

    Вы не написали сообщение

    Нажимая на кнопку "Отправить" Вы даете нам свое согласие на использование указанных Вами здесь данных для обработки Вашего запроса. Передача данных третьим лицам исключена.

    Ваше сообщение отправлено!

    Закрыть

    1
    Рынок B2B
    Сбросить Закрыть
      Показать все свернуть
        Регион поиска
        По всему миру
        Категории
          Наименование позиций