DC Контактор Локомотива

DC Контактор Локомотива

Чаоян, Китай
Начальный
86-010-65761969
jennifer Ding
Контактное лицо

Основные данные

OV195SE low voltage series DC contactors can be applied for railway diesel locomotives, subway rolling stocks, EMU (electronic multiple units), DMU (diesel multiple units) and other industrial electric automation control equipment. Such DC contactors are used to control circuit in locomotives and rolling stocks. The production standards comply with GB/T 21413.1-2008/IEC 60077-1:1999; GB/T 21413.2-2008/IEC 60077-2:1999; and TB/T 2767-1996. Magnetic coil of such DC contactors is equipped with voltage suppressor which can inhibit the self-induced electromotive force of the coil. Auxiliary contact is fast-moving, self-cleaning and sealing OV870W1D1a. Technical Parameters Main Contact Rated Voltage (Ue) DC 110V Rated Current (Ie) (DC-1) DC 250A Auxiliary Contact OV870W1D1a Rated Voltage (Ue) DC 110V Conventional Thermal Current (Ith) DC 5A Rated Current (Ie) (DC-13) DC 0.3A Protection Class (Pollution Level 3) Whole Contactor & Auxiliary Contact Wiring IP00 Auxiliary Contact IP40 Coil Power About 25W Weight (excluding mounting base) OV195SE About 1.6 Kg OV195WE About 1.8 Kg Mechanic Life Over106 times Electric Life Over105 times Models Selection 1- OV195SE series low voltage DC contactors are currently used as contactors of start pumps (QBC) in diesel locomotives. 2- Coil control voltage of OV195SE series low voltage DC contactors can be DC 12V, 24V, 48V and 80V, and coil working voltage is between 80% and 110%. 3- External wiring mode is below: Main Contact: M8 Screw Coil Wiring: M4 Screw Auxiliary Contact: A 6.3/0.8 insert (DIN 41636) 4- When 96V storage battery is used for contactor coil power supply, coil control voltage of the contactor should be 80V which can ensure enough contact pressure. 5- At most 2 sets of auxiliary contact (2 NO + 2 NC) can be installed (Note: OV195WE series DC contactors have no auxiliary contact). 6- When voltage suppressor is parallel connected to two ends of coil, wiring should be as per polarity signs. 7- If main contact of the contactor is permanent magnet and in arc distinguishing mode, wiring should be as per polarity signs. 8- Auxiliary contact OV870W1D1a is conversion type, and NO and NC of a same contact cannot be for a different electric potential. Otherwise, arc short circuit will occur. Please contac us if you are interested in such contactors. Wiring Diagram andStructural Size information is available.

Условия поставки и упаковка

К сожалению продавец не указал условия доставки. За дополнительной информацией обращайтесь к продавцу.

Условия оплаты

Электронный перевод

Вестерн Юнион

Фотографии

    Восстановление пароля
    Для восстановления пароля, введите пожалуйста ниже емаил, на который производилась регистрация:
    Код для сброса пароля был выслан на указанный Вами Email
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    Произошла ошибка. Пожалуйста, проверьте введенные Емаил и повторите попытку.
    Ваш новый пароль:

    Имя не заполнено


    Выберите страну доставки

    Вы не написали сообщение

    Нажимая на кнопку "Отправить" Вы даете нам свое согласие на использование указанных Вами здесь данных для обработки Вашего запроса. Передача данных третьим лицам исключена.

    Ваше сообщение отправлено!

    Закрыть

    1
    Рынок B2B
    Сбросить Закрыть
      Показать все свернуть
        Регион поиска
        По всему миру
        Категории
          Наименование позиций