Место происхождения |
Tianjin China (Mainland) |
Бренд |
TDTF |
Номер Модели |
GWJ-6 |
Patent Product Sience and technology achievement The innovation fund project of National Science and technologyGWJ-6 Particle Counter is designed according to the principle of laser blockage method to size and count the unsolvable particles in injection, transfusion, macroviscosity solution, colored and organic sample particle examination as well as Particle size distribution measurement.Using high brightness laser source, 6-channel. Twelve kinds of particle size can be set.Specification1.Particle Size Range: 1 500μm2.Testing Channels: ≥2um,≥4um,≥5um,≥6um,≥8um,≥10um,≥12um,≥15um,≥20um,≥25um,≥50um, ≥100um3. Sample Volume: 0.5 1000ml4.Sample Flow Rate: 5 80 ml/min, It can be set5. Measurement Range:0 9999999 particles6. Accuracy:stipulate value±10%7.Channel Resolution: >95%(USP)8.Concentration Limit:0 10000 particles/ml (5% coincidence error)9. Repeatability: RSD<2% (Standard particles≥ 1000 particles/ml)10. Stirrer Mode:Magnetic stirring11. Stirring Rate:0 2000 r/min12. Sampling Mode:Sampling head could go up and down automaticlly whose position is adjustable13. Display Operation:Dot matrix LCD display, Film press key, Can be equipped with a standard keyboard14. Data output: Build-in minitype-printer15. Power Supply: 100 264V, 50 60Hz16.Environment Temperature: 10°C 40°C17. Dimension: 360mm x 340mm x 460mm Features 1.The newest model, set the pharmacopoeia detection, anesthesia equipment, may directly have a detection of particulate pollution directly in a variety of packs of injection, asepsis powder, drug packaging materials, and anesthesia utensils, medical apparatus and so on.2.It adopted such a high precision laser sensor, stable performance, wide detection range(1 500μm), not easy to plug, Unique stable optical circuit design of the double-loop to ensure low transmittance light and accuracy of colored sample detection, 3.Advanced precision syringe sampling system,the sampling accuracy is high, stability of speed, Suction capacity is strong, You can directly detect iohexol, high viscosity samples and so on.4.Minimum sample volume is 0.5ml, small injections can be directly detected.5.Sampling head could go up and down automaticlly and the sampling position can be set at random, that take sampling easyin the various amount and packs of injection6. A high degree of intelligence, automatic data of processing and memory, A lattice of big-screen LCD, full menu interface, ease to operate.7.Add a standard keyboard, you can easily and flexibly enter the drug name, batch number, specifications and other information8. Selects magnetic stirrer mode which is used universally in international instruments of the light blockage method. Compared with propeller mixing, it can stir well and not easy to cause air bubble so as to improve detection accuracy and repeatability . (It is easy to interfere with a equipment of laser blockage method by bubbles). It is the advantage that it improve the detection accuracy and repeatability.9. Voltage range: 100 264V, The instrument can overcome the power fluctuations, no need external manostat.