General: PD319-2 Series Multifunctional Harmonic Analyzer is designed for measuring electic parameters, harmonics, multi-rates energy, power quality, S.O.E event reording and communication. They are applied in electric energy management power monitoring and controls, power substation automation, smart building and switchgears, etc. PD319-2 Series Multifunctional Harmonic Analyzer is designed according to (DL/T614-1997, GB/T17883-1999, GB/T17882-1999, DL/T645-1997, GB/T15284-2002, GB/T14549-1993) . Features: 1. The meters can measure 3-phase voltage, 3-phase current, active and reactive power of each phase, total active power, total reactive power, power factor, frequency, 4 quadrant energy. They can measure multi-rate power. 2. The meters can measure the voltage in power network, the harmonic obtained rate of 2 31 times of the current, as well as the total harmonic distortion rate THD. (3 CTs is required). 3. The meters analyze the network voltage, the ponderance and imbalance of current order (positive and negative)(3 CTs is required). 4. With 2 loops of switch input, adoptiing trunk crunode resistance signal input mode. 5. With 2 loops of photo coupler relay switch output, and alarm indication in all environment so as to protect the output control function. 6. The meter supply the active and reactive power pulse output. 7. RS485 communication interface under MODBUS-RTU protocol. 8. The meters can record 20 pieces SOE event. Technical DataAccuracyCurrentvoltage 0.2 class, Frequency 0.1Hz, Power, Active electric energy 0.5class, Reactive electric energy 2 classDisplayLCD DisplayInput measurementNetworkThree Phase Four Line, Three Phase Three LineRated valueVoltage AC100VAC400V, Current AC1AAC5AOverloadingContinuance: 1.2 times, Instantaneous: Voltage 2 time(10s) Current 10 times(5s)Power consumptionVoltage<0.6VA(each phase), Current<0.4VA(each phase)ImpedanceVoltage circuit>300kΩinput measurementFrequency50Hz±10%HarmonicsVoltage, Current(2 31 time) harmonicMnlti-rate electric energy3 rates, 8 time bandsClock/CalendarClock error 0.5s/dayOiwer syookyWorking rangeACDC 80V 270VPower consumption≤5VAOutputDigital InterfaceRS-485 interface, MODBUS-RTU protocolPulse output2 loops power pulse output, Photo-coupler relay, Constant: 3200imp/kWh(kvarh)Switch value output2 loops light couplerlnstallationInstallation modePanel mountingCutout size92x92mmOutline dimension96x96x100mmOperation conditionAmbient temp: -10 55, Relative humidity≤93%, No corrosion air, Height (above sea level)≤2500mIsolation withstand voltageInput and power supply>2kV, Input and output>2kVInsulating resistance≥100MΩTable for Detail FunctionThree Phase Four LineThree Phase Three LinePhase voltageUa, Ub, UcLine voltageUab, Ubc, UcaUab, UcbCurrentIa, Ib, IcIa,IcActive powerPa, Pb, Pc, PPReactive powerQa, Qb, Qc, QQThree Phase Four LineThree Phase Three LineApparent powerSa, Sb, Sc, SSPower factorPFa, PFb, PFC, PFPFVoltage harmonicsUa, Ub, Uc (2 31times)Uab, Ucb (2 31times)Current harmonicsIa, Ib, Ic (2 31times )Ia, Ic (2 31times)Voltage unbalance degreeYvCurrent unbalance degreeYiVoltage componentPositive sequence Up, Negative sequence UnCurrent componentPositive sequence Ip, Negative sequence InFrequencyFActive energy+kWh, -kWhReactive energy+kvarh, -kvarhTime-sharing calculatingPeak, Shoulder, Vally, TotalSOE event reording20 pieces SOE event recordingRemote surveillance input2 loops of switch value inputRemote control output2 loops of switch value outputCommunication interface1 loop of RS-485 interface, MODBUS-RTUPulse output2 loops of energy pulse outputReferenced applicationElectric power system, Transformer, Gen-sets low voltage system wire-in, Energy measurement, Communication and management