Место происхождения |
Shaanxi China (Mainland) |
Бренд |
DKL |
1. Aerosol Fire Suppression System is a new class of fixed fire suppression system using solid propellant aerosol technology. The principle of Aerosol operation is unique-a special solid formulation within a non-pressurized canister, when electrically or thermally activated, generates an aerosol exhibiting excellent fire extinguishing characteristics. The aerosol consists of a suspension of micron sized particles in a mixture of naturally occurring gases comprising mainly of nitrogen. Upon activation, the aerosol propels itself rapidly into the protected area, attacking the fire both chemically and physically, and almost instantaneously extinguishes it. Homogeneous distribution is achieved in a matter of seconds while its long suspension time helps to prevent the fire from reignition. 2. DKL fire suppression systems, can be characterized as requiring no piping, zero storage pressure, solid-state technology, environmentally friendly, non-conductive & non-corrosive, and has significant space & weight advantages in comparision with gaseous systems. 3. Fire Classes According to < Code for Design of Gas Fire Extinguishing Systems> GB 50370-2005 Class A,B,C Applications Power Distribution: Protection of transformers, sub -station, switchgear rooms, cable tunnels, electrical cabinets, power distribution plants, turbine generators, etc. Telecommunications: Protection of switching cabins, server rooms, server farms, data storage, data processing areas, ISP data centre, server and switching cabinets, etc. Marine: Protection of engine rooms, machinery spaces, cargo holds, power boats, super yachts, sail boats, barges, tow boats and control shelters. Construction: Protection of attics, garages, paint lockers, machinery and computer rooms, warehouses, offices, temporary storage, raised floors, etc Transport: Protection of pump rooms, machinery spaces, electrical cabinets, co-generation and electrical distribution systems, mining vehicles, etc. Machinery: Protection of machinery and equipment in factories, inside CNC grinding and turning machines, power cabinet, control cabinets, generator rooms, power switching cabinets, resistor banks, etc. Oil & Gas: Protection of control rooms, switchgear rooms, cable tunnels, pump-stations, pump rooms, machinery spaces, electrical cabinets, cogeneration and electrical distribution systems, petrochemical and pipeline system. Etc. ModelJR0040JR0080JR0120JR0160JR0200JR2000JR4000JR6000JR8000JR100MAerosol Mass,g501001502002502500500075001000012500Generator Mass,kg0.41.51.61.722244487075Max.Protected Volume,m³0.40.81.21.6220406080100Dimensions,mm Length606363120120600800800900900 Diameter80100100144144220300300350350Canister MaterialS/SS/SS/SS/SS/SM/SM/SM/SM/SM/SNozzle OutletLateralLateralLateralLateralLateralD/LateralD/LateralD/LateralD/LateralD/LateralDischarge Time,sec<25< 30< 30< 30< 40<50< 50< 80< 90<100