Place of Origin |
Guangdong China (Mainland) |
Brand Name |
Prostar |
Model Number |
HM15K |
Weight |
212Kg |
Output Voltage |
220V ±1% |
Neptune SeriesLow FrequencyOnlineUPS→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→ Applied Scope: Data Center Medical And Health Industrial Equipment Energy And Electricity Financial And Securities Large Internet Computer Room Postal And Telecommunications Industrial And Commercial tax affair Main Characteristics:Durable and reliable design of industrial-type modular structure, combined with full digital DSP control technology core system, make this product not only can be used for N+1/N+X redundancy and the ability of enlarge the capacity, but also permit different power and different times of the UPS could be in parallel. It greatly reduced the user's pre-and post-purchasing costs, and increased capacity costs, but also expanded upper spaces of increasing capacity.Technical Specification:HM8K HM15K (Three-ins & Single out)ModeHM8KHM10KHM15Capacity(VA/W)8K/6.4K10K/8K15K/12KBattery Voltage384VUPS Efficiency≥95%Noise48 54dB (Distance 1m)Size(W×D×H mm)550×720×1200Weight(Kg)(Excluding battery)180186212InputVoltage3 phases 4 wires and ground, 380V ± 20%Frequency50Hz/60Hz ± 5% (Automatically)Power Factor≥0.95Inverter outputVoltage220V ±1%Frequency50Hz/60Hz±0.05%(By battery)Harmonic distortionLinear load< 3%, Non-linear load < 5%Imbalance VoltageBalance load ≤ 1%, Imbalance load ≤3%Phase shift angleBalance load≤±1°, Imbalance load≤±2°Transient responseOutput at 0 50% 100% ≤5%, response≤10msOverload Capacitance110%≥300 Min, 125%≥10 Min, 150%≥ 1 MinCrest Factor3:1Wave FormPure Sine WaveTransfer time0 msBatteryMax.charging current0.2A x C10Charging Time(Standard)12 hoursSystemProtective functionInput Over-voltage, under-voltage; Output overload, short-circuit;Inverter over-temperature; Battery under-voltage, over-voltageRunning temperature& Humidity0°C-40°C degree Celsius,less than 95%(without condensing)Altitude<1000m(with increase of 100m, it will reduce output of 1% )max 4000mCommunication interfaceRS232Remote signalDry contact ( battery low, battery discharging, bypass/fault); EPORemote controlEPO and BypassDegree of ProtectionIP20 (front door opened)Parallel modeN+1,N+X can be in parallel with different power capacitySoftware InterfaceWindows9X,2000,NT,Me,XP,Linux,Novell,Macosx,NT4.0Mean time between failures300,000 HoursotherDustproof and damp-proof, isolating inverter transformer, Lightning Surge absorption, static switches and manual maintenance switchNoted: Products specifications are subject to update, if you would like to knowlatestinformation, please contact us.