Place of Origin |
China (Mainland) |
Brand Name |
MEAN WELL |
Model Number |
ELN-60-12 |
Input Voltage |
90~264VAC |
Output Voltage |
DC 12V |
Output Current |
0~5.0A |
Output Type |
Single |
MODEL ELN-60-12OUTPUTDCVOLTAGE 12V LED OPERATION VOLTAGE 3 12V RATEDCURRENT 5A CURRENTRANGE 0 5A RATEDPOWER 60W RIPPLE&NOISENOTE.2 120MVP-P VOLTAGE ADJ RANGE 10.8 13.2V Can be adjusted by intemal potential meter SVR1 VOLTAGETOLERANCENOTE.3 ±5.0% LINEREGULATION ±1.0% LOADREGULATION ±2.0% SETUP.RISEHOLD.TIME 500ms, 30ms/230VAC 1500ms,30 / 115VAC at full load HOLD UP TIME(TYP) 50ms /230VAC 16ms/115VAC at full load INPUTVOLTAGERANGE 90 264VAC FREQUENCYRANGE 47 63HZ EFFICIENCY 85% AC CURRENT 1.2A/115VAC 0.7A/230VAC INRUSH CURRENT Cold start 60A/230vac LEAKAGECURRENT 0.25mA/240VAC PROTECTIONOVER CURRENT 95 110% Protection typeConstant current limiting,recovers automatically after fault condition is removed OVER VOLTAGE 13.8 16V Protection typeShut down o/p voltage,re-power on to recover. FUNCTIONDIMMING CONTROL (OPTIONAL) 1 10VDC or PWM signal:100HZ 3KHZ ENVIRONMENTWORKINGTIMP -20 +60(refer to output load derating curve) WORKINGHUMIDITY -20 90%Rhnon-condensing STORAGE TEMP HUMIDITY -40 +80 10 95%RH TEMPCOEFFICIENT ±0.03%(0 50) VIBRATION 10 500HZ,2G10min/1cycle period for 60 min each alongX,Y,Zaxes SAFETY&EMCSAFETYSTANDARDS Design refer to UL1310 Class 2,TUV EN60950-1,EN61347-2-13,CAN/CSA C22.2 NO.223-M91M,IP67 approved WITHSTAND VOLTAGE 1/P-0/P:3KVAC ISOLATIONRESISTANCE 1/P-0/P:>100M Ohms/500VDC/25/70%RH EMI CONDUCTICN& RADIATION Compliance to EN55022(CISPR22)classB HARMONICCURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11 ENV50204,EN50204,EN61000-6-1 Light industry level criteriaA QTHERSMTBF 603Khrs min MIL-HDBK-217F(25) DIMENSION 181*61.5*35mm(L*W*H) PACKING 0.4Kg 24pcs / 11Kg / 0.75CUFT NOTE1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.3. Tolerance : includes set up tolerance, line regulation and load regulation.4.Derating may be needed under low input voltage.please check the derating curve for more details.5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meet EMC directives.6.Length of set up time is measured at first.tuming ON/OFF the power supply may lead to increase of the set up time .7.Output voltage can be adjusted though the SVR1 on the PCB;limit of output constant level can be adjusted though the SVR2 on the PCB.8.Constant current operation region is within the specified output voltage above. This is suitable operation region for LED related applications.