250W enclosed switching power supply(S-250series)

250W enclosed switching power supply(S-250series)

Yueqing, China
Production capacity:
1000 Piece / Week
Yueqing, China
Company
86-0577-61755289
XiuQin Xu
Contact person

Basic Information

Place of Origin Zhejiang China (Mainland)
Brand Name HAN RI
Model Number S-250series
Input Voltage Other
Weight 1.15Kgs
Output Power 201 - 300W
Output Type Single
S-250 Series switching power supplyCompetitivedprice and high reliability105oC Output capacitorAC input power suitable for the worldHigh efficiency and low operation temperatureSoft-start current can reduce the AC input impact effecticlyWith short-circuit and overload protectionCompact size, light weight100% full-load burn-in testInstalled with EMI filter, minimum waveModelS-250-12S-250-13.5S-250-15S-250-24S-250-27S-250-48DC output voltage12V13.5V15V24V27V48VOutput voltage range(Note:2)±1%±1%±1%±1%±1%±1%Rated output current20A18A16.6A10.4A9.2A5.2AOutput current range0-20A0-18A0-16.6A0-10.4V0-9.2V0-5.2VWave and noise(Note:3)150mVp-p150mVp-p150mVp-p150mVp-p150mVp-p150mVp-pInlet stability(Note:4)±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%Load stability(Note:5)±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%DC output power240W243W249W249.6W 248.4W249.6WEfficiency82%83%84%86%86%87%Adjustable range for DC voltage10 13.2V12 15V13.5 18V20 26.4V26 32V41 56VAC input voltage range88 132VAC/176 264VAC selected by switch 47 63Hz;Input current6A/115V 3.5A/230VAC inrush current20A/115V 40A/230VLeakage current<3.5mA/240VACOverload protection105% 150% Type: pulsing hiccup shutdown Reset: tuto recoveryTemperature coefficient±0.03%/°c(0 50°c)Setup, rise , hold up time2s, 20ms, 20msVibration10 500Hz, 2G 10min,/1cycle, Period for 60min, Each axesWithstand voltageInput and output internal: Input and encolsur: 1.5KvAC, Output and enclosure: 0.5KvACIsolation resistanceInput and output internal: Input and enclosure, Output and enclosure:500VDC/100MΩWorking temperature and humidity-10°c +60°c(Refer to output derating curve), 20% 90%RHOverall dimension215×115×50mmWeight1.15KgsSafety standardsDesign refer to UL 1950Note: 1. The testing condition for the paramenter above is: 230VAC input, rated load, 25°c 70% RH. Temperatuer. 2. Error: include the setting error, line stability and load stability.(Note:5) 3. Wave test: adopting "A12" double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting. 4. Inler woltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage. 5. Load stability test: The load is from 0% to 100%

Delivery terms and packaging

Port: Ningbo

Payment term

Telegraphic transfer

Western Union

Фотографии

    Password recovery
    To recover your password, please enter in the box below your email address with which you have registered:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    An error has occurred. Please check your e-mail address and try again.
    Ваш новый пароль:

    Name is empty


    Выберите страну доставки

    You have not written a message

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    Your message has been sent!

    Close

    1
    Рынок B2B
    Cancel Close
      Show more close
        Area search
        Worldwide
        Категории
          Product