120W SMPS(S-120-12)

120W SMPS(S-120-12)

Yueqing, China
Production capacity:
1000 Piece / Week
Yueqing, China
Company
86-0577-61755289
XiuQin Xu
Contact person

Basic Information

Brand Name HANRI
Place of Origin Zhejiang China (Mainland)
Model Number S-120-12
Input Voltage 110V
Output Voltage 12V
Output Current 10A
Weight 0.66Kgs
Output Power 101 - 200W
Output Type Single
S-120 series SMPSCompetitivedprice and high reliability 105oC Output capacitorAC input power suitable for the world High efficiency and low operation temperature Soft-start current can reduce the AC input impact effeciticly With short-circuit and overload protection Compact size, light weight 100% full-load burn-in test Installed with EMI filter, minimum waveModelS-120-3S-120-5S-120-7.5S-120-12S-120-15S-120-24S-120-27S-120-48DC output voltage3V5V7.5V125V15V24V27V48VOutput voltage range(Note:2)±2%±2%±1%±1%±1%±1%±1%±1%Rated output current22A24A16A10A8A5A4.4A2.5AOutput current range0-22A0-24A0-16A0-10A0-8A0-5A0-4.4A0-2AWave and noise(Note:3)100mV100mV100mV100mV100mV100mV100mV100mVInlet stability(Note:4)±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%Load stability(Note:5)±0.5%±1%±0.5%±0.3%±0.3%±0.2%±0.3%±0.2%DC output power66W120W120W120W120W120W119W120WEfficiency70%78%80%81%81%84%84%84%Adjustable range for DC voltage2.85 3V4.75 5.5V6.75 8.25V10.8 13.2V13.5 16.5V21.6 26.4V26 32V43.2 52.8VInput current2.4A/115V 1.2A/230VAC inrush currentCold-start current 30A/115V 60A/230VLeakage current<1mA/240VACOverload protection105% 150%150% 200%105% 150% Type: Output shutdown Reset: Recycle AC ON/OFFTemperature coefficient±0.03%/°c(0 50°c)Setup, rise , hold up time200ms,100ms, 30msVibration10 500Hz, 2G 10min,/1cycle, Period for 60min, Each axesWithstand voltageInput and output internal: 1.5KvAC, Input and enclosure:1.5KvAC, Output and enclosure:0.5KvACWorking temperature and humidity-10°c +60°c(Refer to output derating curve), 20% 90%RHWeight0.66KgsSafety standardsMeet UL 1012 requirementNot apply forr the markEMC standardsMeet FCC PART 15 J Conduction class BNote: 1. The testing condition for the paramenter above is: 230VAC input, rated load, 25°c 70% RH. Temperatuer. 2. Error: include the setting error, line stability and load stability.(Note:5) 3. Wave test: adopting "A12" double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting. 4. Inlet woltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage. 5. Load stability test: The load is from 0% to 100%

Delivery terms and packaging

Port: Ningbo

Payment term

Telegraphic transfer

Western Union

Фотографии

    Password recovery
    To recover your password, please enter in the box below your email address with which you have registered:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    An error has occurred. Please check your e-mail address and try again.
    Ваш новый пароль:

    Name is empty


    Выберите страну доставки

    You have not written a message

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    Your message has been sent!

    Close

    1
    Рынок B2B
    Cancel Close
      Show more close
        Area search
        Worldwide
        Категории
          Product