Ort der Herkunft |
China (Mainland) |
Marke |
MEAN WELL |
Modell-Nummer |
DRP-240-24 |
Eingangsspannung |
80~132VAC |
Ausgangsspannung |
DC 24V |
Ausgangsstrom |
0~10A |
Ausgangstyp |
Einzel |
MODEL DR-240-24OUTPUTDCVOLTAGE 24V RATEDCURRENT 10A CURRENTRANGE 0 10A RATEDPOWER 240W RIPPLE & NOISE (max.) Note.2 80MVP-P VOLTAGEADJ.RANGE 24 28V VOLTAGE TOLERANCE Note.3 ±1.0% LINEREGULATION ±0.5% LOADREGULATION ±1.0% SETUP.RISEHOLD.TIME 800ms,40ms/230VAC 800ms, 40ms/115VAC at full load HOLD UP TIME (Typ.) 24ms/230VAC 24ms/115VAC at full load INPUTVOLTAGERANGE Note.6 85 264VAC 120 370VDC FREQUENCYRANGE 47 63HZ POWER FACTOR (Typ.) 0.96/230VAC 0.99/115VAC at full load EFFICIENCY (Typ.) 84% AC CURRENT (Typ.) 2.8A/115VAC 1.4A/230VAC INRUSH CURRENT (Typ.) COLD START 27A/115VAC 45A/230VAC LEAKAGE CURRENT <3.5mA / 240VAC PROTECTIONOVERLOAD 105 150%rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed OVER VOLTAGE 30 36V Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE 100±5 (TSW1) detect on heat sink of power transistor Protection type : Shut down o/p voltage, recovers automatically after temperature goes down ENVIRONMENTWORKING TEMP -10 +70 (refer to output load derating curve) WORKINGHUMIDITY 20 90% RH non-condensing STORAGE TEMP HUMIDITY -20 +85, 10 95%RH TEMPCOEFFICIENT ±0.03%(0 50) VIBRATION Component:10 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 SAFETY&EMCNote 4)SAFETY STANDARDS UL508, UL60950-1, TUV EN60950-1 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATIONRESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTICN& RADIATION Compliance to EN55011, EN55022(CISPR22)classB HARMONICCURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A QTHERSMTBF 105.5Khrs min MIL-HDBK-217F(25) DIMENSION 125.5*125.2*100mm(L*W*H) PACKING 1.2Kg; 12pcs / 15.5Kg / 1.29CUFT NOTE1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.3. Tolerance : includes set up tolerance, line regulation and load regulation.4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meetsEMC directives.5. Derating may be needed under low input voltages. Please check the derating curve for more details.