Ort der Herkunft |
China (Mainland) |
Marke |
MEAN WELL |
Modell-Nummer |
RSP-3000-48 |
Eingangsspannung |
180~264VAC |
Ausgangsspannung |
48VDC |
Ausgangsstrom |
0~62.5A |
Ausgangstyp |
Einzel |
MODEL RSP-3000-48OUTPUTDC VOLTAGE 48V RATED CURRENT 62.5A CURRENT RANGE 0 62.5A RATED POWER 3000W RIPPLE & NOISE (max.) Note.2 200MVP-P VOLTAGEADJ.RANGE 43 56V VOLTAGE TOLERANCE Note.3 ±1.0% LINEREGULATION ±0.5% LOADREGULATION ±0.5% SETUP,RISE TIME 1000ms,80ms at full load HOLD,TIME(TYP.) 10ms at full load INPUTVOLTAGERANGE Note.5 180 264VAC 254 370VDC FREQUENCYRANGE 47 63HZ POWER FACTOR (Typ.) 0.95/230VAC at full load EFFICIENCY (Typ.) 90.5% AC CURRENT (Typ.) 20A/180AVC 16A/230VAC INRUSH CURRENT (Typ.) 60A/230VAC LEAKAGECURRENT <2.0mA / 240VAC PROTECTIONOVERLOAD 100 112%rated output power User adjustable continuous constant current limiting or constant current limiting with delay shutdown after 5 seconds, re-power on to recover OVER VOLTAGE 57.6 67.2V Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE 90± 5 (12V), 100± 5 (24V,48V) (TSW1: detect on heatsink of power transistor) Protection type : Shut down o/p voltage, recovers automatically after temperature goes down 90 ±5 (12V), 85± 5 (24V), 80± 5 (48V) (TSW2 : detect on heatsink of o/p diode) FUNCTION AUXILIARY POWER(AUX) 12V @ 0.1A (Only for Remote ON/OFF control) REMOTE ON/OFF CONTROL Note.6 Please see the Function Manual ALARM SIGNAL OUTPUT Please refer to function manual OUTPUT VOLTAGE TRIM Note.6 9.6 56V CURRENT SHARING(CS)Note.7 Please refer to function manual ENVIRONMENT WORKING HUMIDITY 20 90% RH non-condensing WORKING TEMP. -20 +70 (Refer to output load derating curve) STORAGE TEMP HUMIDITY -40 +85 10 95%RH TEMPCOEFFICIENT ±0.05%(0 50) VIBRATION 10 500HZ,2G10min/1cycle,60min.each alongX,Y,Zaxes SAFETY &EMC(Note 4)SAFETY STANDARDS UL60950-1, TUV EN60950-1 approved/ 25 / 70% RH WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATIONRESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTICN& RADIATION Compliance to EN55022 (CISPR22) HARMONICCURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A QTHERSMTBF 104.5Khrs min MIL-HDBK-217F(25) DIMENSION 278*177.8*63.5mm (L*W*H)) PACKING 4Kg; 4pcs/16Kg/1.89CUFT NOTE1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.3. Tolerance : includes set up tolerance, line regulation and load regulation.4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meetsEMC directives.