Ort der Herkunft |
Zhejiang China (Mainland) |
Marke |
Meanwell |
Modell-Nummer |
HLG-150-24 |
Eingangsspannung |
90 ~ 264VAC127-370VDC |
Ausgangsspannung |
24VAC |
Ausgangsstrom |
3.15-6.3A |
Ausgangsleistung |
101 - 200W |
Ausgangstyp |
Einzel |
MODELHLG-150-24OUTPUTDC VOLTAGE24VCONSTANT CURRENT REGION Note.412-24VRATED CURRENT6.3ACURRENT ADJ.RANGECan be adjusted by internal potential mater or through output cable3.15-6.3ARATED POWER150WRIPPLE & NOISE (max.) Note.2150mVP-PVOLTAGE ADJ. RANGE Note.622-27VVOLTAGE TOLERANCE Note.3±1.0%LINE REGULATION±0.5%LOAD REGULATION±0.5%SETUP.RISE TIME Note.92500ms, 50ms at full load 230VAC/115VACHOLD UP TIME(Typ.)16ms at full load 230VAC/115VACINPUTVOLTAGE RANGE Note.590 264VAC 127-370VDCFREQUENCY RANGE47 63HZPOWER FACTORPF>0.95/230VAC PF≥0.98/115VAC at full load and rated output voltage PF≥0.9 at 50-100% loadEFFICIENCY (Typ.)94%AC CURRENT1.2A/115VAC 1A/230VACINRUSH CURRENT (Typ.)COLD START 75A/230VACLEAKAGE CURRENT≤0.75mA / 277VACPROTECTIONOVER CURRENT Note.495-108%Protection type:Constant current limiting,recovers automatically after fault condition is removedSHORT CIRCUIT Note.7Hiccup mode,recovers automatically after fault condition is removedOVER VOLTAGE28-34VProtection type : Shut down o/p voltage with auto-recovery or re-power on to recoveryOVER TEMPERATURE110°C±10°C(RTH2)Protection type:Shut down o/p voltage,re-power on to recoverENVIRONMENTWORKING TEMP-30° +60°C @full load;+70°C @60%load(refer to derating curve)WORKING HUMIDITY20 95% RH non-condensingSTORAGE TEMP HUMIDITY-40 +80°C 10 95%RHTEMP. COEFFICIENT±0.03%/°C (0 50°C)VIBRATION10 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axesSAFETY&EMCNote 4)SAFETY STANDARDSUL1012 ; EN61347-1, EN61347-2-13 independent (except for HLG-120 C type) ; UL60950-1,TUV EN60950-1WITHSTAND VOLTAGEI/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVACISOLATION RESISTANCEI/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25°C/70% RHEMI CONDUCTION&RADIATIONCompliance to EN55015,EN55022(CISPR22)Class BHARMONIC CURRENTCompliance to EN61000-3-2,Class C(≥60% load);EN61000-3-3EMS IMMUNITYCompliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, heavy industry level (surge 4KV), criteriaAOTHERSMTBFKhrs min. MIL-HDBK-217F(25°C)DIMENSION212.2*68*38.8mm (L*W*H)(HLG-120-Blank/A/B) 219*68*38.8mm (L*W*H)(HLG-120-C)PACKINGKGNOTE1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and25°C of ambient temperature.2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.3. Tolerance : includes set up tolerance, line regulation and load regulation.4.Constant current operation region is within 50%-100% rated output voltage.This is the suitable operation region for LED related applications,but please reconfirm special electrical requirements for some specific system design.5. Derating may be needed under low input voltage. Please check the derating curve for more details.6.Type A and Type C only7.Please refer to OLP characteristics.8.Safety and EMC design refer to EN60598-1,subject 8750(UL),CNS15233,GB7000.1,FCC part 18.9.Length of set up time is measured at cold first start.Turning ON/OFF the power supply may lead to increase of the set up time.